PFC Air – Cooling for PTV Injectors

Gas chromatography and GC/MS

PFC Air – Cooling for PTV Injectors

Chromtech

PFC stands for PTV Fast Cooling. PFC Air accelerates the cooling of compressed air-cooled PTV injectors in GC and GC/MS systems and replaces additional cryogenic cooling media with electrically generated Peltier colds.

Manufacturer
Chromtech
Product range
Gas chromatography and GC/MS
Advice
Direct from Chromtech

Option for GC and GC/MS

Faster back to the initial temperature.

PTV Fast Cooling

In the case of short gas chromatographic methods, the cooling time of the PTV injector can delay the next measurement start. PFC Air supports compressed air-cooled PTV injectors with electrically generated and stored Peltier cold. As a result, low initial temperatures can be reached more quickly without additionally cooling with liquid nitrogen or liquid carbon dioxide.

  • Retrofittable for conventional compressed air-cooled PTV injectors
  • Suitable for systems from Agilent, Gerstel, JAS, ATAS and Bruker, among others
  • No additional cryogenic cooling media required
  • PFC pre-cooling to at least 35 K below laboratory temperature
  • Depending on the type of injector at 50 °C oven temperature in about three minutes to below 5 °C
  • Faster readiness for the next run and thus higher sample throughput
  • Option for gas chromatography and coupled GC/MS and GC-MS/MS systems

Terms: PFC stands for PTV Fast Cooling, meaning rapid cooling of a PTV inlet. PTV denotes a programmable temperature vaporising inlet. GC/MS means gas chromatography with mass spectrometry; GC-MS/MS combines gas chromatography with tandem mass spectrometry. Cryogenic media here are liquid nitrogen and liquid carbon dioxide. A temperature difference of 35 K corresponds to cooling by 35 °C.

In practice

PFC on the Agilent GC/MS system.

Yassin Hardi reports on the installation of an Agilent 8890 GC with 5977B mass spectrometer and Chromtech PFC. The Peltier cooling system preheats compressed air or nitrogen in order to cool the temperature-programmable injector more quickly after running.

The paper mentions applications with large-volume sample application and QuEChERS sample preparation. A CombiPAL-xt takes over the liquid and headspace injection; in addition, a Chromtech He-EcoSaver is installed in the described plant.

QuEChERS is an extraction and cleanup method frequently used for pesticide analysis.

Practical report on LinkedIn →
Agilent 8890 with 5977B mass spectrometer, Chromtech PFC, CombiPAL-xt and He-EcoSaver
PFC in an Agilent GC/MS system

In practice

PFC in the Evolution3 system in Tübingen.

Yassin Hardi reports on a Chromtech Evolution 3 installation at the University of Tübingen. The GC-MS/MS system combines triple quadrupole analysis with PFC cooling and automated SPDE sample preparation.

PFC cools the compressed air with Peltier elements and thus supports the cooling of the Agilent MMI injector. PAL-based SPDE handles solvent-free dynamic microextraction prior to analysis with Evolution3.

MMI refers here to the versatile, temperature-programmable Agilent injector; SPDE stands for solid-phase dynamic extraction.

Practical report on LinkedIn →
Chromtech Evolution3 at the University of Tübingen with PFC cooling and PAL-based SPDE
Evolution3 with PFC and SPDE at the University of Tübingen

Advice and integration

For the appropriate system configuration.

Whether this product fits your application depends on the sample, method and existing device environment. We clarify the requirements, coordinate the configuration and accompany the integration into your laboratory process.

Appropriate applications