Conditioning
The cartridge is wetted with solvent, emptied and prepared for sample loading with a defined air buffer.

Laboratory automation
Chromtech
The Chromtech SPE option automates solid phase extraction on the RTC PAL. Suitable commercially available cartridges are processed with a pressure-tight connection and controlled positive pressure for sample loading, washing and elution.
Automated solid phase extraction
The SPE option developed by Chromtech adds a fully automated solid phase extraction workflow to the RTC PAL. Suitable commercially available cartridges from different manufacturers, already established in manual sample preparation, can be used.
Solid phase extraction concentrates target analytes and removes interfering components of the sample matrix. This can improve chromatographic sensitivity and support lower detection limits.
The SPE cartridge is coupled to the delivery system with a pressure-tight connection. The sample, wash solution and eluent are driven through the sorbent under controlled positive pressure. The closed flow path prevents uncontrolled leakage at the coupling point.
Workflow videos
The videos are loaded directly from this website. No connection to YouTube or another video service is required.
The cartridge is wetted with solvent, emptied and prepared for sample loading with a defined air buffer.
The system takes the sample from the fraction collector and applies it to the prepared SPE cartridge.
After washing, the cartridge is dried under nitrogen before the concentrated analytes are eluted.
The concentrated analytes are eluted into the sample vial with a defined volume of chloroform in this example method.
The PAL automatically transports the SPE cartridge to the PrepStation and positions it for the next step.
The sample is passed slowly through the SPE cartridge in a controlled process.
The sample vial is opened and the eluent is applied to the SPE cartridge.
After elution, the sample vial is closed and returned to the sample tray.
The movement across the system shows the paths between the sample tray, fraction collector and PrepStation.
Terms: SPE means Solid Phase Extraction. The sorbent is the solid material inside the cartridge that retains target analytes during sample loading.
In practice
Yassin Hardi presents Chromtech SPE automation on the RTC PAL under the name PrepStar. The video shows an automated sequence of cartridge conditioning, sample loading, washing and elution.
Suitable commercially available SPE cartridges can be configured for the method. Drying and automatic opening and closing of sample vials can be added where required.
Based on the public demonstration by Yassin Hardi. Cartridge type and process parameters are selected for the application.
SPE demonstration on LinkedIn →System compatibility
This option is configured for the PAL RTC. We assess the sample, method and existing equipment before agreeing on the configuration.
RTC PAL systems →Advice and integration
Whether this product fits your application depends on the sample, method and existing equipment. We clarify your requirements, agree on the configuration and support integration into your laboratory workflow.