Chromtech-Produkte
In-house developments and practical extensions.
Chromtech solutions complement existing analytical systems and help to improve sample introduction, automation and routine operation.
21 Product pages
Gas chromatographyLarge Volume Pyrolysis
The large Chromtech pyrolysis oven automates large-volume pyrolysis for microplastics analysis. Large ceramic sample crucibles, PAL RTC, RSI and DHR and a heated transfer line connect sample preparation with GC-MS analysis.
Chromtech
Laboratory automationRobotic LIMS-to-Vial Labeler
The robotic LIMS-to-Vial labeler from Chromtech automatically labels sample vessels with QR code and plain text from LIMS working lists. A robot takes the vessels from the supply tray, guides them to the labeling system and deposits them in the target tray.
Chromtech
GC/MSChromtech Evolution3 GC-MS/MS (QQQ)
Chromtech Evolution3 extends existing Agilent MSD systems to a triple quadrupole GC-MS/MS. MS/MS selection suppresses chemical substrate and improves sensitivity, especially in complex sample matrices.
Chromtech
Manufacturers and partnersChromtech product portfolio
Chromtech product portfolio stands for a coordinated portfolio of analytical systems and complementary solutions.
Chromtech
Gas chromatographyeTrap cold trap for GC systems
The Chromtech eTrap focuses highly volatile compounds electrically and without cryogenic cooling media. eTrap and eTrap Plus support splitless headspace, SPDE, SPME, thermodesorption and purge-and-trap applications.
Chromtech
GC/MSHe-EcoSaver – helium savings option for GC and GC/MS
The Chromtech He-EcoSaver reduces the helium consumption of GC and GC/MS systems: During the measurement, helium serves as a carrier gas, while in standby mode, the system can automatically switch to nitrogen.
Chromtech
Laboratory automationHeatedTray PAL3 R60
HeatedTray PAL3 R60 from Chromtech is available for PAL RTC, RSI and DHR and retrofits an existing tray holder for the temperature control of 20 ml sample vessels. It reaches with heat coverage up to 60 °C. A removal tool lifts ten sample vessels from the tray at the same time.
Chromtech
Laboratory automationIceStar with ThermoTray
IceStar is a robust multipurpose cooling system for CTC-PAL sample racks. According to the Peltier liquid cooling principle, it quickly lowers the temperature to up to 20°C below the ambient temperature – without liquid nitrogen or liquid carbon dioxide. ThermoTray is also available for PAL RTC and RSI.
Chromtech
Laboratory automationPAL Options
PAL options automates recurring steps of sample preparation and sample introduction.
Chromtech
Laboratory automationPAL classic
PAL classic are used samplers from CTC Analytics, which Chromtech completely overhauls, technically modernizes and carefully checks. They receive a twelve-month warranty and can be integrated into standard chromatography data systems.
Chromtech / CTC Analytics
Laboratory automationPAL3 - SyFi - Syringe Filter Option
The Chromtech SyFi option automates syringe filtration of small sample volumes on the RTC PAL. The optional GL Sciences EZ Cartridge RP-1 extends sample preparation with SPE enrichment. Configuration and method are tailored to the application.
Chromtech
Laboratory automationPAL3 SPE
PAL3 SPE automates the solid phase extraction on the RTC PAL with commercially available SPE cartridges. A pressure-tight connection couples the cartridge to the conveying system and moves sample and process solutions through the sorbent in a controlled manner under overpressure.
Chromtech
Laboratory automationPAL3 TDAS 2020
Chromtech’s PAL3 TDAS 2020 automates thermal desorption at the RTC PAL. A mobile furnace transfers volatile and less volatile compounds directly from the sample tube into the GC injector – without an additional transfer line.
Chromtech
Laboratory automationPAL3 ThermoTray
PAL3 ThermoTray from Chromtech is designed for VT15 and VT54 aluminum racks and is connected to a circulation cooler. Delivery is without racks.
Chromtech
Laboratory automationPCS Peltier Cooled Syringe
PCS Peltier Cooled Syringe automates recurring steps of sample preparation and sample introduction.
Chromtech
Gas chromatographyPFC Air – Cooling for PTV Injectors
PFC stands for PTV Fast Cooling. PFC Air accelerates the cooling of compressed air-cooled PTV injectors in GC and GC/MS systems and replaces additional cryogenic cooling media with electrically generated Peltier colds.
Chromtech
Laboratory automationSample preparation with glass pipettes
The Chromtech option automates the uptake and distribution of defined liquid volumes with glass pipettes. Samples, solvents and internal standards can be distributed on vials or SPE glass columns and integrated into reproducible purification processes. In addition, the cooled PAL3 tray holder “Pipette Tube” and a second version with cooled vials for sample collection are available.
Chromtech
Laboratory automationSingle Magnet Mixer
The single magnet mixer (SMM) from Chromtech automatically stirs and tempers samples. It is available for PAL3 RTC and RSI from CTC Analytics as well as for the older PAL-classic generation.
Chromtech
Laboratory automationSP400 – SPME conditioning station
SP400 is a Chromtech PAL3 option for thermally conditioning SPME fibers under carrier gas. After extraction and desorption, it prepares the fiber for the next sample and reduces carryover. Also available for older PAL systems.
Chromtech
Laboratory automationSPDE – The Magic Needle
SPDE from Chromtech enriches compounds from liquid samples or the gas space above them. An internally coated needle extracts the fabrics dynamically and releases them in the hot GC injector. Automated with PAL RTC and PAL RSI.
Chromtech
Laboratory automationSPME Option for CTC PAL/PAL-xt
SPME Option for CTC PAL/ PAL-xt automates recurring steps of sample preparation and sample introduction.
Chromtech