Application · Laboratory automation

Reliably automate recurring processes.

From sample preparation to sample introduction, we combine modules, tools and analytical systems into a clearly defined process.

Automated sample preparation

SPE and syringe filtration compared

Enrich target compounds, remove matrix components or separate particles: suitable sample preparation depends on your analytical task. Compare the Chromtech PAL3 SPE and SyFi options with the standalone AquaTrace ASPE900 from GL Sciences.

Comparison of enrichment, platform, sample volume, transfer and workflow
CriterionCHROMTECH PAL3 SPECHROMTECH PAL3 SyFiGL Sciences AquaTrace ASPE900
TechniqueSolid-phase extraction (SPE).Syringe filtration for particle removal.Solid-phase extraction (SPE) for water samples.
EnrichmentYes, retain target compounds on the sorbent and elute them.No with a syringe filter; yes with an optional SPE membrane cartridge, depending on the method.

Enrichment option: EZ Cartridge RP-1

Yes, by SPE; additional evaporation within the system.
PlatformChromtech option for PAL3 RTC.Chromtech option for PAL3 RTC.Standalone system; not a PAL option.
Samples and volumesLiquid samples; volumes depend on the method.Small liquid volumes, low dead volumes.Water samples; adjustable from 10 to 99,990 mL.
Delivery principleControlled positive pressure; pressure-tight cartridge coupling.A syringe pushes the sample through the filter membrane.Valveless piston pump.
Cartridge or filterCommercially available SPE cartridges from different manufacturers.Method-specific syringe filters; typical pores 0.02 to 5.0 µm.Luer connection; 6 mL syringe barrels as standard.
Automated workflowCondition, load sample, wash, dry and elute.Pick up the sample and filter, then filter the sample.SPE workflow including drying and evaporation.
Key strengthIntegrate SPE into a programmable PAL workflow.Filter into open vials or suitably configured closed vials.Process up to six samples in parallel.

SPE means solid-phase extraction: target compounds are retained on a sorbent and subsequently eluted. SyFi stands for syringe filter. Filters, cartridges, volumes and process steps are selected to suit the sample and method. The ASPE900 volume range is an adjustable instrument range.

Automation concept

The right level of automation.

Assess the workflow

Capture manual steps, sample numbers and critical handovers in the existing process.

Connect the modules

Configure autosamplers, tools and analyzers to fit the task.

Ensure reliable routine operation

Testing sequences, documenting them and transmitting them in a comprehensible manner for operators.

Our options

Process consultancy services

Which work step do you want to automate?

A short description of the sample, the number of pieces and the current procedure is sufficient for the start.

Describe your workflow →